Gas Technician 3 (G3): O. Reg. 215/01 supervision rules, O. Reg. 212/01, gas properties, piping, pressure testing, purging, venting basics and controls
Practice on the go and jump straight back to where you left off.
About the certification
In Ontario, work on gas appliances and gas piping is regulated by the Technical Standards and Safety Authority (TSSA). The Gas Technician 3 (G3) is the entry-level certificate: under O. Reg. 215/01, s. 22, a G3 does listed functions under general supervision, or any function of the supervisor's certificate under direct supervision, and may never perform the initial activation of a new appliance.
The pass mark for TSSA Gas Technician exams is 75% (EX 01). TSSA does not publish the number of questions on the official exam, so ExamHub's Test Mode draws 100 questions as a practice length. CSA B149.1-25 is adopted in Ontario from 2026-06-01 (TSSA document FS-279-26).
ExamHub's free G3 practice test has 200 original questions, each with an explanation and a free public source.
What's covered
Categories cover G3 scope: regulations, piping and testing, basic combustion and venting, controls and safety.
Try a few
Five sample questions from the question bank, with the answer and explanation.
Why: Section 22(2) bars a G3 from the initial activation of a new or newly converted appliance. Reactivating a previously installed appliance, cleaning and lubricating it, and replacing a vent connector are all listed in s. 22(1).
Why: Clause 6.23.4 c) i) requires the discharge point to be at least 10 ft (3 m) from a source of ignition, with maximum precautions taken to remove or shut off any ignition source before purging begins. The 25 ft (7.5 m) figure belongs to mechanical air intakes.
Why: Category I appliances operate with nonpositive vent static pressure and a flue loss of at least 17% (efficiency about 83% or less), such as a standard natural-draft furnace. Category II keeps nonpositive pressure but has lower flue loss; III and IV run at positive pressure.
Why: An unloaded thermocouple should read about 30 mV and is replaced if it produces under 20 mV. About 15 mV is the expected closed-circuit (under load) reading, where under 10 mV means replacement.
Why: The 24-hour limit is 10 ppm, set to protect people with coronary artery disease from heart-related effects. The 25 ppm value is the shorter 1-hour limit, and higher values are closer to workplace exposure limits.
FAQ
No. This is unofficial study practice written from free public sources: Ontario e-Laws (O. Reg. 215/01, O. Reg. 212/01, the TSSA Act), the TSSA Code Adoption Document FS-279-26 and open fuel gas textbooks. It does not reproduce the licensed CSA B149.1 code text or real exam questions.
Test Mode draws 100 questions with a 75% pass mark, the pass mark for TSSA Gas Technician exams (EX 01). TSSA does not publish the number of questions on the official exam, so 100 questions is ExamHub's practice length, not the official length.
Under O. Reg. 215/01, s. 22, a G3 may do only the listed functions under general supervision, or any function of the supervising G1, G2 or DA certificate under direct supervision, and may never perform the initial activation of a new appliance. A G2 is a separate certificate with its own scope (s. 21), and ExamHub will have a separate G2 practice test.
TSSA's Gaseous Fuels Code Adoption Document FS-279-26 adopts CSA B149.1-25 (with Ontario amendments) from 2026-06-01, alongside O. Reg. 212/01 (Gaseous Fuels). ExamHub cites only free public text and never reproduces paywalled CSA content.
No. These are original practice questions with an explanation and a named source for every answer. They are not copies of exam questions.