Gasfitter Class A Red Seal Practice Quiz
Free · 151 Questions.

Based on the Red Seal Gasfitter – Class A exam blueprint: flame safeguard sequencing, valve trains, interlocks, plant piping, venting and air supply, testing, commissioning and service

📝 100 Q practice test✅ Pass: 70%⏱ Up to 4 hr🔁 Free retakes Updated: October 2026
⚠️ExamHub is an independent study resource and is not affiliated with, endorsed by, or reviewed by the Red Seal program, any apprenticeship authority or the Canadian Standards Association. Questions are original practice materials.
Choose your mode
Mode 1
Test Me
100 questions with a 240-minute timer. 70% (70/100) to pass, with complete answer review at the end.
⏱ 240 min100 Qs70% to passAnswer review
Mode 2
Practice
Sequential practice with detailed explanations after every question. Numbered navigator with auto-saving progress.
📖 Explanations🔊 Voice narrationAuto-save
Or practice by topic
Common Occupational Skills
8 questions
Fuel Piping and Tubing
14 questions
Venting, Air Supply and Draft
20 questions
Controls and Electrical
28 questions
Appliances, Conversions and Storage
20 questions
Testing and Commissioning
34 questions
Service, Repair and Decommissioning
27 questions
📲 Add Gasfitter Class A Red Seal Practice Quiz to your Home Screen

Practice on the go and jump straight back to where you left off.

About the certification

Gasfitter – Class A (Red Seal)

Gasfitter – Class A is a Red Seal trade for large commercial and industrial gas systems: appliances above 400 000 Btuh (120 kW), burner management and flame safeguard systems, plant piping, venting and air supply, and the CSA B149 codes. Licensing rules differ by province, so check with your apprenticeship or safety authority. ExamHub's questions follow the 2024 Red Seal Occupational Standard.

The Red Seal exam has 100 multiple-choice questions in 7 blocks: common skills (5 questions), piping and tubing (9), venting and air supply (13), controls and electrical (19), appliances, conversions and storage (13), testing and commissioning (23) and service (18). Between 60 and 70% of the questions test procedures and their application, 15 to 25% knowledge and recall, and 10 to 20% critical thinking. The pass mark is 70% and the writing time is four hours (exam details as of October 2026).

ExamHub's free practice quiz has 151 original questions weighted to those blocks, with an explanation and a source for every answer. The questions cover flame safeguard sequencing, valve trains, interlocks, calculations from the Red Seal formulas sheet, pressure testing and purging, and draw on public TSSA, Alberta and manufacturer documents.

Sources: Red Seal Occupational Standard 2024, the Red Seal exam-information page, the Exam Preparation Guide, TSSA code adoption documents and Alberta STANDATA bulletins. Exam details as of October 2026. See how ExamHub checks its questions.

What's covered

151 practice questions, by category

Categories group the seven Red Seal exam blocks, weighted like the real exam.

BlockExam questionsBank questions
A. Common skills58
B. Piping and tubing914
C. Venting and air supply1320
D. Controls and electrical1928
E. Appliances and storage1320
F. Testing and commissioning2334
G. Service1827

Topic breakdown

  • Common Occupational Skills8
  • Fuel Piping and Tubing14
  • Venting, Air Supply and Draft20
  • Controls and Electrical28

 

  • Appliances, Conversions and Storage20
  • Testing and Commissioning34
  • Service, Repair and Decommissioning27

Try a few

Sample Gasfitter Class A practice questions

Five sample questions from the question bank, with the answer and explanation.

Question 1
A burner management control cannot establish pilot flame within the selected pilot trial for ignition period. What does a flame safeguard control do, according to Fireye's service guide?
  • Locks out on safety and needs a manual reset
  • Opens the main valve to prove the flame at low fire
  • Recycles indefinitely until the pilot lights
  • Bypasses the flame signal and continues the sequence

Why: The pilot trial for ignition (PTFI) is the maximum time allowed to establish and detect the pilot flame. Failure within that period causes the flame safeguard system to lock out on safety, requiring a manual reset. A control never proceeds to the main valve without proven pilot flame.

Question 2
A mechanical-draft boiler fires 1 500 000 Btuh of natural gas at 1 000 Btu/ft3. Using 10 ft3 of theoretical air per ft3 of gas and 50% excess air, what volume of combustion air plus excess air is needed per hour?
  • 22 500 ft3/h
  • 15 000 ft3/h
  • 7 500 ft3/h
  • 33 750 ft3/h

Why: Gas flow is 1 500 000 / 1 000 = 1 500 ft3/h. Theoretical air at 10:1 is 15 000 ft3/h, excess air at 50% is 7 500 ft3/h, so the total is 22 500 ft3/h. Giving only the theoretical air, only the excess, or adding a dilution volume the burner does not have are the usual errors.

Question 3
A natural gas engine drives a generator and has an input of 4 MMBtu/h. What number of safety shut-off valves, with which arrangement, does B149.1:25 Annex N require?
  • One valve marked C/I, with no proof of closure switch
  • Two valves piped in parallel, each without a C/I marking
  • Three valves, with a vent valve between the second and third
  • Two valves marked C/I, piped in series and wired in parallel

Why: For an engine or turbine up to 2.5 MMBtu/h, one C/I-marked safety shut-off valve or two valves are allowed (two minimum for propane). Above 2.5 and up to 5 MMBtu/h, at least two safety shut-off valves are required, each marked C/I, piped in series and wired in parallel. Proof of closure becomes mandatory above 5 MMBtu/h.

Question 4
A plant fuel gas line has a design pressure of 150 psig and will be hydrostatically tested. What is the minimum hydrostatic test pressure under B149.1:25 clause 6.22.8?
  • 150 psig
  • 180 psig
  • 300 psig
  • 225 psig

Why: The hydrostatic test pressure at every point in the system shall not be less than 1.5 times the design pressure: 1.5 x 150 = 225 psig. It is maintained at least 30 minutes or as long as needed to inspect joints, and the system is then fully drained and dried.

Question 5
A combustion analyzer on a natural gas boiler shows 9.0% CO2 in the flue gas. The stoichiometric CO2 for the fuel is 11.7%. Using the Red Seal formula, what is the excess air?
  • 23%
  • 77%
  • 130%
  • 30%

Why: The Red Seal formula is % CO2 = stoichiometric CO2 / (1 + excess air / 100). Rearranged, 1 + EA/100 = 11.7 / 9.0 = 1.30, so excess air is 30%. The values 77% and 23% come from dividing the wrong way round, and 130% forgets to subtract the 1.

FAQ

Gasfitter Class A questions, answered

How many questions are on the Gasfitter Class A Red Seal exam?

The Red Seal exam has 100 multiple-choice questions. ExamHub's bank has 151 questions, and Test Mode draws 100 for a 240-minute timed simulation.

What is the pass mark and the time limit?

According to the Red Seal Exam Preparation Guide, the pass mark is 70% and the writing time is four hours. ExamHub's Test Mode uses the same time.

What topics are on the Red Seal Gasfitter Class A exam?

Seven blocks: common skills (5 questions), piping and tubing (9), venting and air supply (13), controls and electrical (19), appliances, conversions and storage (13), testing and commissioning (23) and service (18). Commissioning and controls, including flame safeguard systems, carry the most weight.

Do I need the CSA B149.1 code book to use this quiz?

No. The CSA B149 codes are paid documents and are not reproduced here. Each question cites the Red Seal standard and the public document (regulator bulletin, manufacturer literature, open textbook) that quotes or explains the clause. Questions that rest on an Ontario or Alberta rule say so.

Are these the real exam questions?

No. These are original practice questions written from the Red Seal standard and free public sources. They are not copies of exam questions.

Other free practice tests

Gasfitter Class B (Red Seal)
158 questions
158 questions on gas piping, venting and air supply, controls, appliances, testing and service.
TSSA G3 Gas Technician
200 questions
G3 certificate: O. Reg. 215/01 supervision, gas properties, piping and testing, venting basics and controls.
307A Steamfitter
205 questions
205 questions on steam systems, layout geometry, process piping, and rigging.