Oil Heat System Technician Practice Quiz
Free · 167 Questions.

Based on the Red Seal Oil Heat System Technician exam blueprint: fuel storage and supply, appliances, venting and combustion air, electrical systems, and maintenance and diagnosis

📝 110 Q practice test✅ Pass: 70%⏱ Up to 4 hr🔁 Free retakes Updated: October 2026
⚠️ExamHub is an independent study resource and is not affiliated with, endorsed by, or reviewed by the Red Seal program or any provincial or territorial apprenticeship authority. Questions are original practice materials.
Choose your mode
Mode 1
Test Me
110 questions with a 240-minute timer. 70% (77/110) to pass, with complete answer review at the end.
⏱ 240 min110 Qs70% to passAnswer review
Mode 2
Practice
Sequential practice with detailed explanations after every question. Numbered navigator with auto-saving progress.
📖 Explanations🔊 Voice narrationAuto-save
Or practice by topic
Common Occupational Skills
11 questions
Fuel Storage and Supply
30 questions
Appliances, Forced-Air and Hydronic Systems
35 questions
Venting, Combustion Air and Make-up Air
26 questions
Electrical and Electronic Systems
33 questions
Maintenance, Diagnosis, Repair and Removal
32 questions
📲 Add Oil Heat System Technician Practice Quiz to your Home Screen

Practice on the go and jump straight back to where you left off.

About the certification

Oil Heat System Technician (Red Seal)

Oil Heat System Technician is a Red Seal trade. These technicians install, retrofit, maintain, diagnose and repair oil-fired heating appliances, fuel storage and supply systems, venting, combustion air and the electrical controls that run them. The Red Seal Interprovincial Examination is the national exam for the trade. In Ontario, oil burner technicians are certified through TSSA (OBT-1, OBT-2 and OBT-3) instead, so this quiz follows the national Red Seal standard and not Ontario certificate scopes.

The Red Seal exam has 110 multiple-choice questions in 6 major work activities: common occupational skills (7 questions), fuel supply and storage systems (20), oil-fired heating systems (23), venting, combustion air and make-up air (17), electrical and electronic systems (22), and maintenance, diagnosis, repair and removal (21). Between 65 and 75% of the questions test procedural knowledge and application, 10 to 20% knowledge and recall, and 10 to 20% critical thinking. The pass mark is 70% and the writing time is four hours. A short formula sheet is provided with the exam.

ExamHub's free practice quiz has 167 original questions weighted to those activities, with an explanation and a source for every answer. They are written from the Red Seal standard, NRCan's Heating with Oil guide, the burner, control, nozzle and tank manufacturers' instructions, and public regulator documents. The CSA B139 installation code is a paid standard that SkilledTradesBC lists as supplied at the exam sitting, so ExamHub does not reproduce it: the questions ask what the technician does and why.

Sources: the Red Seal Oil Heat System Technician exam information and the Red Seal Exam Preparation Guide. See how ExamHub checks its questions.

Exam details as of October 2026.

Exam format and ExamHub bank
ItemRed Seal examExamHub bank
Format110 multiple-choice questions167 multiple-choice questions
Pass mark70%70% (Test Mode)
Time4 hoursUp to 4 hours (Test Mode)
A Common occupational skills711
B Fuel supply and storage systems2030
C Oil-fired heating systems2335
D Venting, combustion air and make-up air1726
E Electrical and electronic systems2233
F Maintenance, diagnosis, repair and removal2132

What's covered

167 practice questions, by category

Categories group the 18 Red Seal exam tasks, weighted like the real exam.

Topic breakdown

  • Common Occupational Skills11
  • Fuel Storage and Supply30
  • Appliances, Forced-Air and Hydronic Systems35

 

  • Venting, Combustion Air and Make-up Air26
  • Electrical and Electronic Systems33
  • Maintenance, Diagnosis, Repair and Removal32

Try a few

Sample Oil Heat System Technician practice questions

Five sample questions from the question bank, with the answer and explanation.

Question 1
An obround steel tank 1,400 mm long is being set on its legs. The manufacturer requires a minimum slope of 10 mm per 500 mm toward the fuel outlet. What is the minimum difference in height between the two ends of the tank?
  • 28 mm
  • 14 mm
  • 35 mm
  • 50 mm

Why: Slope is rise divided by run. The tank must fall 10 mm for every 500 mm of length, so over 1,400 mm the minimum drop toward the outlet is 1,400 / 500 x 10 = 28 mm. Using 1,400 / 1,000 x 10 gives 14 mm, and rounding the run up to 1,750 mm would give 35 mm. The slope keeps water and sludge moving toward the outlet end, where they can be seen and removed.

Question 2
An oil furnace and water heater with a total input of 150,000 Btu/h are in a small room that draws combustion and ventilation air from inside the building. What air openings does the burner manufacturer require for this confined space?
  • Two permanent openings, one near the top and one near the bottom, each with a free area of at least 150 sq in.
  • One permanent opening near the top of the room with a free area of at least 150 sq in., since warm air rises
  • Two permanent openings, one near the top and one near the bottom, each with at least 37.5 sq in. of free area
  • Two permanent openings, one near the top and one near the bottom, each with at least 75 sq in. of free area

Why: For an appliance in a confined space the manufacturer requires two permanent openings, one near the top and one near the bottom of the enclosure. Each must have free area of not less than 1 sq in. per 1,000 Btu/h of the total input of all appliances in the enclosure: 150,000 / 1,000 = 150 sq in. each. The 37.5 and 75 sq in. values correspond to 1 sq in. per 4,000 and per 2,000 Btu/h, which are for outdoor-air arrangements.

Question 3
A nozzle stamped 0.85 gph is rated by its maker at 100 psi. The boiler manufacturer specifies a pump pressure of 140 psi. What is the actual nozzle flow at that pressure?
  • 1.01 gph
  • 1.19 gph
  • 0.72 gph
  • 0.85 gph

Why: Nozzle flow changes with the square root of the pressure ratio: 0.85 x square root of (140 / 100) = 0.85 x 1.183 = 1.01 gph, which matches the manufacturer's flow chart. Multiplying by the pressure ratio itself (1.4) gives 1.19 gph, dividing by the square root gives 0.72 gph, and the stamped 0.85 gph applies only at 100 psi.

Question 4
While the burner is running, a technician presses and releases the reset button of an R7184 to read the cad cell, and the LED flashes four times. What does this mean?
  • The resistance is above 1,600 ohms, too high; clean the lens, check the sighting or replace the cell
  • The cad cell resistance is below 400 ohms, which is the best reading the control can show
  • The control has locked out four times in a row and has entered restricted lockout mode
  • The cad cell resistance is between 800 and 1,600 ohms, which is acceptable but marginal

Why: In the cad cell resistance check, one flash means 0-400 ohms, two flashes 400-800 ohms, three flashes 800-1,600 ohms and four flashes above 1,600 ohms. For proper operation the resistance must be below 1,600 ohms, so four flashes is a fault: the lens is cleaned, the view of the flame checked, or the cell replaced. Restricted lockout is shown by a different flash pattern.

Question 5
A technician closes the burner's air setting down to a trace of smoke and reads 13.5% CO2. Following the burner manufacturer's procedure, what are the CO2 and smoke readings after the final setting?
  • About 11.5% to 12.0% CO2, with a smoke reading of zero
  • About 13.5% CO2, with a smoke reading of trace
  • About 9.5% to 10.0% CO2, with a smoke reading of zero
  • About 14.5% CO2, with a smoke reading of zero

Why: The trace-of-smoke point is the reference. The air is then increased until the CO2 is 1.5 to 2 percentage points lower: from 13.5% to 11.5% (about 12%). The smoke level is rechecked and should be zero, which gives a margin of reserve air for variable conditions. Leaving the burner at a trace of smoke leaves no margin; CO2 cannot rise as the air is increased.

FAQ

Oil Heat System Technician questions, answered

How many questions are on the Oil Heat System Technician Red Seal exam?

The Red Seal exam has 110 multiple-choice questions with four options each. ExamHub's bank has 167 questions, and Test Mode draws a 110-question timed simulation.

What are the pass mark and the time limit?

The Red Seal pass mark is 70% and the writing time is four hours. ExamHub's Test Mode uses the same 70% pass mark and up to 240 minutes.

What topics are on the exam?

6 major work activities: common occupational skills (7 questions), fuel supply and storage systems (20), oil-fired heating systems (23), venting, combustion air and make-up air (17), electrical and electronic systems (22), and maintenance, diagnosis, repair and removal (21).

Do I need the CSA B139 code book to use this quiz?

No. SkilledTradesBC lists the CSA B139 Series 24 code book as supplied at the exam sitting. ExamHub does not reproduce the code; its questions rest on public documents such as NRCan's guide and manufacturers' instructions and ask what to do and why.

Is this the same as the Ontario oil burner technician (OBT) certificate?

No. In Ontario the credential is the TSSA oil burner technician certificate (OBT-1, OBT-2 or OBT-3). This quiz follows the national Red Seal standard, so it does not test Ontario certificate scopes or Ontario amendments to the code.

Are these the real exam questions?

No. These are original practice questions written from the Red Seal standard and free public sources. They are not copies of exam questions.

Other free practice tests

313A Refrigeration & A/C
150 questions
150 questions on refrigeration theory, charging, and commissioning.
307A Steamfitter
205 questions
205 questions on steam systems, layout geometry, process piping, and rigging.
Plumber Level 1
161 questions
161 questions on safety, tools, trade math, drawings and piping.
Gasfitter Class B (Red Seal)
158 questions
158 questions on gas piping, venting and air supply, controls, appliances, testing and service.
TSSA G2 Gas Technician
148 questions
148 questions on G2 appliances, water heaters, furnaces, hydronic heating, venting and controls.
CCQ Plumber (Pipe Fitter) Exam
147 questionsNew
147 questions on Quebec Plumbing Code rules: drainage, venting, water supply, tests, safety on site and maintenance.
TSSA OBT-3 Oil Burner Tech
150 questions
150 questions on OBT-3 scope, tanks and piping, burners, controls, venting and combustion.
TSSA Propane PPO-3 (ROT)
146 questions
PPO-3 cylinder filling: inspection and collar stamps, the 42% / 80% fill limits, trade measurement and O. Reg. 215/01.